Tolerance

  Panel Tolerances (as Manufactured)
  Panel Size - Molded, Compression Molded   +/-1/8" (width, length & diagonal)
  Panel Size - Pultruded   +-1/4" (width, legnth & diagonal)
  Grating Depth   +/-1/16"
  Panel Flatness (Wrap)   +/- 1/32" per If (lenght direction)
    +/- 1/16" per If (width direction)
 
  Cutting Tolerances (as Fabricated)
  Rectangular Cuts   +0", -1/4"
  Straight Cuts   +0", -1/4"
  Circular Cuts   +0", -3/8"
   
  Grating Clearances
  To Side of Trench   1/4"
  To Wall   1/2"
  Between Panels   0" to 1/4"1
  
  Minimum Support Width   11/2" minimum (nominal)
 
  Attachment   2 Anchors at Each Support
 
  Banding
  Plate 1/8" (min) attached with bolts or lag screws
  Straight Banding - attachments spaced 12" centers
  Curved Banding - attachments spaced 9" max (dependant on radius)
 
  Stair Treads
  Nosing = "Readily Identifiable" - solid, color difference from tread, etc.
  Recommended Tread Attachment to Stringer
  4 Anchors per Tread
  Support - FRP Angle - 2"x2"x1/4" minimum x full tread run, in Length
  1. Molded grating is generally manufactured to true size - 4'x8', 3'x10', etc. Some field trimming may be required.
  2. The above tolerances for Flatness (Warp) does not apply to favricated panels.
  3. Theres tolerances do not apply to grating panels covered with plate (laminated or adhesixe bonded).