| Load
Table - Metric Units |
|
|
CONCENTRATED LINE LOAD
- DEFLECTION TABLE (IN MILLIMETERS)
|
|
SPAN
(mm)
|
DEPTH
(mm)
|
MESH
(mm x mm)
|
LOAD = KN/M²
|
MAXIUM
RECOM-MENDED |
ULTIMATE
CAPACITY
|
|
3
|
5
|
8
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
80
|
90
|
100
|
KN
|
KN
|
|
400
|
25
|
25 x 100
|
1.22
|
2.05
|
3.27
|
4.12
|
6.17
|
8.23
|
10.29
|
12.35
|
16.46
|
-
|
-
|
-
|
-
|
-
|
8
|
0
|
|
25
|
38 x 38
|
1.64
|
2.75
|
4.39
|
5.52
|
8.27
|
11.03
|
13.79
|
16.55
|
22.06
|
-
|
-
|
-
|
-
|
-
|
9
|
46
|
|
38
|
38 x 38
|
0.62
|
1.05
|
1.67
|
2.12
|
3.17
|
4.23
|
5.29
|
6.35
|
8.46
|
10.58
|
12.69
|
16.93
|
19.04
|
-
|
18
|
91
|
|
50
|
50 x 50
|
0.31
|
0.54
|
0.85
|
1.08
|
1.62
|
2.17
|
2.70
|
3.25
|
4.32
|
5.42
|
6.49
|
8.67
|
9.74
|
11.91
|
29
|
146
|
|
600
|
25
|
25 x 100
|
3.50
|
5.85
|
9.35
|
11.72
|
17.57
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
6
|
31
|
|
25
|
38 x 38
|
4.60
|
7.69
|
12.29
|
15.38
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
7
|
36
|
|
38
|
38 x 38
|
1.54
|
2.59
|
4.13
|
5.18
|
7.77
|
10.37
|
12.95
|
15.55
|
-
|
-
|
-
|
-
|
-
|
-
|
14
|
71
|
|
50
|
50 x 50
|
0.88
|
1.49
|
2.37
|
2.98
|
4.47
|
5.97
|
7.45
|
8.95
|
11.92
|
14.92
|
17.89
|
-
|
-
|
-
|
22
|
111
|
|
800
|
25
|
25 x 100
|
8.30
|
13.85
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
5
|
26
|
|
25
|
38 x 38
|
10.88
|
18.15
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
4
|
21
|
|
38
|
38 x 38
|
3.28
|
5.49
|
8.77
|
10.98
|
16.47
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
11
|
56
|
|
50
|
50 x 50
|
1.82
|
3.05
|
4.87
|
6.12
|
9.17
|
12.23
|
15.29
|
18.35
|
-
|
-
|
-
|
-
|
-
|
-
|
13
|
66
|
|
1000
|
38
|
38 x 38
|
6.78
|
11.32
|
18.10
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
8
|
41
|
|
50
|
50 x 50
|
3.62
|
6.05
|
9.67
|
12.12
|
18.17
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
11
|
56
|
|
1200
|
38
|
38 x 38
|
11.58
|
19.32
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
6
|
31
|
|
50
|
50 x 50
|
6.05
|
10.10
|
16.15
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
9
|
46
|
|
1400
|
50
|
50 x 50
|
9.68
|
16.15
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
6
|
31
|
| Note: |
Ultimate
capacity is the load at which the grating fails totally.
Maximum recommend load represents a 5:1 safety factor of ultimate
capacity. |
|